NET.Pro Heat Recovery Ventilator(HRV)

NET.Pro Heat Recovery Ventilator(HRV) NET.Pro Heat Recovery Ventilator(HRV) NET.Pro Heat Recovery Ventilator(HRV)

NET.Pro Heat Recovery Ventilator(HRV)
The MENRED NET. Pro Series Heat Recovery Ventilator is a cost-efficient way to ensure fresh, climate-controlled indoor air. It employs a heat exchange core to transfer heat or cool air from the exhaust air to the incoming fresh air. By using the outgoing stale air to heat up or cool down the incoming fresh air, our heat recovery ventilator ensures a constant supply of fresh and comfortable air, reduces energy consumption, and cuts costs.


 The MENRED NET. Pro Series Heat Recovery Ventilator, designed to transfer heat or cool air from exhaust air to fresh air. This ventilation solution efficiently removes excess moisture, odors, and contaminants while saving energy and enhancing comfort.

we offer a superior Heat Recovery Ventilator designed to provide fresh, clean incoming air with maximum energy efficiency.

Our innovative cartridge design adopts multiple filtration stages, including a screen and a high-efficiency cartridge to increase the dust capacity of the product, which significantly extends the life of the cartridge. Our filtration system effectively removes PM2.5 particles, ensuring that the air you breathe is healthy and clean.

The exchange core of our Heat Recovery Ventilator features a large size rhombic countercurrent paper total heat exchange core, which enables both temperature exchange and enthalpy exchange. This system allows for superior heat transfer efficiency, increasing energy efficiency and cost savings.

The MENRED Heat Recovery Ventilator is an excellent solution for those seeking a cost-effective and efficient way to improve indoor air quality while reducing energy consumption. By providing fresh, clean air at maximum efficiency, our system ensures maximum comfort and healthy living.



Features:

1. Micro-positive pressure avoids dirty air from entering the room through the door and window cracks, ensuring a good environment is maintained in the room.

2. The cartridge adopts multiple filtration (screen + high efficiency cartridge) to greatly increase the dust capacity of the product, making the life of the cartridge significantly increased, and can efficiently filter PM2.5.

3. The modular design of the junction box facilitates the electrical maintenance of the product.

4. The exchange core adopts large size rhombic countercurrent paper total heat exchange core can realize temperature exchange and enthalpy exchange.

5. Main board control, stable performance, full functionality (reserved for 485 communication, air valve interface and other functions).


Selection Table:

ModelNET.150.ProNET.250.ProNET.350.Pro
Voltage(V/Hz)220/50220/50220/50
Air volume(m³/h)150/125/100250/200/120350/250/150
Power(W)106/99/33136/115/95170/145/122
Noise(dB(A))30/25/2334/26/2337/34/25
Weight(KG)212428
Filter modelF109;F152F198;F153F199;F154
Filter classAir inlet:H13(1); Return air inlet: H11(1)Air inlet:H13(1);Return air inlet: H11(1)Air inlet: H13(1); Return air inlet:H11(1)

FAQs

How enthalpy exchanger works? How enthalpy exchanger works?
By recovering and reusing the energy from the exhaust air, enthalpy exchangers effectively reduce the energy demand of the HVAC system, improve indoor air quality, and enhance overall energy efficiency in buildings.
Read More
Filter replacement Filter replacement
1、When the controller cartridge progress bar shows red, please replace the cartridge in time. 2、Open the middle gland plate of the exchange core in the direction as shown. 3、Take out the cartridge in the direction of the figure and replace it. 4、Put the replaced cartridge into the corresponding slot and cover the exchange core gland. 5、Open the cartridge setting page of the controller and press and hold the cartridge progress bar for 5 seconds to reset the cartridge balance, and the display shows 100% that the reset is successful. Note: Steps 1 and 5 are required for CLS4.0S LCD controller, if you purchase other controllers, please refer to the manual of the controller.
Read More
How many modes of Menred G3 ventilator can be set? How many modes of Menred G3 ventilator can be set?
Energy saving mode: The air volume of exhaust air and fresh air are equal. Default wind speed is low speed. Haze removal mode: The fresh air is high speed, the exhaust air is low speed, and the wind speed shows high speed. Sleep mode: Both fresh air and exhaust air are low speed, wind speed shows low speed. Auto mode: Automatically adjust the airflow level according to the indoor CO2 and PM2.5 concentration. User can set the corresponding value in the setting page. For example, when PM2.5 is set to High > 100 > Medium > 35 > Low and C02 is set to High > 1500 > Medium > 700 > Low, when the air quality sensor detects PM2.4 > 100 and CO2 is between 700 and 1500, the wind speed is high.
Read More
what is an enthalpy exchanger what is an enthalpy exchanger
Enthalpy exchangers are particularly useful in climates where there are significant temperature and humidity differences between the indoor and outdoor environments. Apart from transferring sensible heat (temperature), they also transfer latent heat (moisture) between the airstreams, providing the benefits of both heat and moisture recovery.
Read More
Why do our home need ERV ventilation? Why do our home need ERV ventilation?
When two people sleep for seven hours, their sweating and breathing produce approximately 7.5 to 8 decilitres of moisture and about 150 to 200 litres of carbon dioxide. They also release some 250 to 300 watts of heat to indoor air. If the moisture content of indoor air rises too high, the moisture condensates in the windows or in the structures of the cold external wall. Structures that have become moist are breeding grounds for microbes and mould fungi, which will before long cause damage to the structures. Almost all fungal mycelia grow at a relative moisture of more than 80% and in normal room temperature. Efficient ventilation removes the carbon dioxide and moisture load as well as smells, taking them out of the house.
Read More
When should I replace the filter? When should I replace the filter?
The default setting of filter life is 6 months(which can be reset in WeChat). After using for 6 months, the filter icon will flash to remind the user to replace the filters. After replacing the filter, long press the filter button for 5 seconds to reset the time.
Read More
How to choose the suitable type of ventilator? How to choose the suitable type of ventilator?
If the area of a computer room is 60 sq meter(S=60), the net height is 3 meters(H=3), and there are 10 persons(N=10) in it. If it is calculated according to “Personal fresh air consumption”, and assume that:Q=70, the result is Q1=N*Q=10*70=700m³/h If it is calculated according to “Air change per hour”, and assume that: P=5, the result is Q2=P*S*H=5*60*3=900m³/h Since Q2>Q1,Q2 is better for selecting the unit. As to special industry such as hospitals(surgery and the special nursing rooms), labs, workshops, airflow required should be determined in conformity with regulations concerned.
Read More